Retinal Imaging: Purpose, Procedure, Risks, Resutls

27 May.,2024

 

Retinal Imaging: Purpose, Procedure, Risks, Resutls

Retinal imaging takes a digital picture of the back of your eye. It shows the retina (where light and images hit), the optic disc (a spot on the retina that holds the optic nerve, which sends information to the brain), and blood vessels. This helps your optometrist or ophthalmologist find certain diseases and check the health of your eyes.

Read more

Doctors have long used a tool called an ophthalmoscope to look at the back of your eye. Retinal imaging allows doctors to get a much wider digital view of the retina. It doesn&#;t replace a regular eye exam or regular dilation but adds another layer of precision to it.

Your doctor may recommend it if you have any the following diseases or conditions:

Diabetes: This disease can damage the blood vessels in your retina. Over time, it causes you to lose your sight if it is not controlled.

Macular degeneration: The central part of your retina (the macula) starts to get worse with age. You may have blurry vision and find it harder to focus. If that happens, you may be considered legally blind even though you may still have peripheral vision. There are two kinds of macular degeneration: wet and dry.

Dry macular degeneration is by far the most common form of this disease (up to 90% of the cases). It happens when blood vessels under the retina become thin and brittle.

Abnormal blood vessels growing under the retina cause wet macular degeneration. Vision loss is usually fast.

Retinal imaging is very important in finding this type of macular degeneration.

Glaucoma: This disease damages your optic nerve (located in the retina) and may cause vision loss. It typically happens when fluid builds up in the front of your eye. It can cause blindness but it normally progresses slowly and can be treated with special eye drops to lower the pressure caused by the fluid.

Retinal Toxicity: The arthritis drug hydroxychloroquine (Plaquenil) can damage your retina.

Your doctor may also use retinal imaging if your vision is getting worse and they aren&#;t sure why.

Fundus Camera - StatPearls

Continuing Education Activity

The fundus camera is an instrument used for fundus photography. Fundus photography captures the images of the retina, optic nerve head, macula, retinal blood vessels, choroid, and the vitreous. Fundus photography impacts the detection and screening of various causes of treatable and preventable blindness, notably diabetic retinopathy, age-related macular degeneration, glaucoma, and retinopathy of prematurity. Over the decades, the quality of fundus images and the ease of photography has improved significantly. This activity describes the techniques of fundus photography and the use of fundus cameras for the management of various ophthalmic conditions and highlights the role of the interprofessional team in evaluating and managing the diseases of the vitreo-retina and optic nerve head with fundus photography.

Objectives:

  • Describe the principles of commonly used fundus cameras.

  • Outline the anatomy and physiology of the ocular fundus related to imaging and indications of various fundus cameras.

  • Review the clinical significance of fundus photography.

  • Summarize the technique and personnel involved in fundus photography and the role of interprofessional collaboration in improving patient care.

Access free multiple choice questions on this topic.

Introduction

Fundus photography is taking the image of the retina of the eye with a fundus camera. Fundus photography is important for diagnosing and treating various posterior segments and other ocular diseases. The illumination and reflectance of the retina occur through the common optical path, i.e., the pupil. Jackman and Webster were the first to publish retinal photographs in .[1] Carl Zeiss was the first commercially available fundus camera in .[1] Hansell and Beeson attached the electronic flash tube enabling light to be directed through the pupil.[2] 

Over time, sharper images, non-mydriatic cameras, pupil tracking, smart- fundus imaging, ultrawide field fundus imaging, and artificial intelligence (AI) integrated into online or offline photography have resulted from technical advances in retinal imaging.

Anatomy and Physiology

The retina is the neurosensory part of the eye where light impulses from an object are converted to electoral impulses that travel to the brain, and the person receives the details of the object. The imaging of the retina poses difficulty because the retina must be illuminated and imaged simultaneously through a narrow pathway, i.e., the pupil.[3] 

The retina is a minimally reflective surface; hence, the back reflections from the retinal surface are lesser than the combined reflections from the illuminating and imaging systems. The fundus camera uses the principle of reflex-free indirect ophthalmoscopy. Traditional fundus cameras use the rim of the pupillary aperture for illumination and the center of the pupil for imaging (Figure-1). With this, the overlapping reflections are minimized.

Indications

Any pathology of the posterior segment of the eye can be detected with a fundus camera. The common indications are enumerated in the following table.

Table

Serial No. Sub-Specialties

Contraindications

Absolute contraindications: There are no absolute contraindications to fundus imaging.

Possible difficulties during fundus photography:

  • Musculoskeletal diseases may not allow the patient to keep the chin in the chin rest.

  • Severe photophobia in conditions like an acute ocular injury may cause blepharospasm and increased lacrimation creating a challenge for a good capture.

Equipment

A fundus camera is a complex system with multiple lenses and a camera utilizing the principle of indirect ophthalmoscope (Figure-2). The parts of a typical fundus camera are shown in the figure (Figure-3).

Optics of Fundus Camera

Light from the viewing lamp is projected onto a round mirror (Figure-4, round mirror-1) and then through a set of filters (Figure-4, filters) onto another round mirror (Figure 4, round mirror -2). The light is reflected from the mirror (round mirror-2) to a series of lenses (Figure 4, series of lenses).  

Due to the presence of a mask in the uppermost lens (Figure 4, uppermost lens), the light is finally focused as a donut-shaped beam. This donut-shaped light beam falls on another round mirror with a central aperture (Figure-4, round mirror-3 with a central aperture), and the reflection exits the camera system through the objective lens and enters through the cornea into the eye (Figure-4, donut-shaped light through a dilated pupil), the photo of which is to be taken.

When both the illuminating rays through the pupillary border and the image at the center of the pupil are correctly aligned, the imaging rays exit through the center of the pupil, i.e., the central non-illuminated portion of the donut of the light (Figure-1, Figure-4, donut-shaped light through a dilated pupil)

The imaging rays pass through the central aperture of the mirror as mentioned above (Figure-4, round mirror-3 with a central aperture), through the astigmatic correction and diopter compensation lenses (Figure-4, diopter compensation lenses), then back to the single-lens reflex camera system (Figure-4, camera system).

The commonly used table-top fundus cameras include iCam (Optovue Inc. Fremont, CA), 3nethra (Forus Inc. Bengaluru, India), digital retinography system (dRS, CenterVue, Padova, Italy), EasyScan (iOptics, Den Haag, The Netherlands), TRCNW8Fplus (Topcon, Tokyo, Japan), Visucam (Zeiss, Oberkochen, Germany), Nonmyd7 (Kowa, Torrance, CA), and Canon CR-2 ( Canon, Tokyo, Japan).[1]

Over time, there have been many upgrades to the traditional table-top fundus camera. These are as described below. 

Wide-field and ultra-widefield fundus cameras:

Wide-field fundus imaging refers to taking retinal images of more than 50 degrees.[25] Ultra-wide-field fundus imaging was defined by DRCR.net (diabetic retinopathy clinical research network) to be more than 100 degrees of field of area.[26] 

Recently a consensus nomenclature defined wide-field imaging (WFI) to be a single captured retinal image centered on the fovea and extending beyond the posterior pole but posterior to the vortex vein ampullae in all the four quadrants. Ultra-wide-field image (UWFI) is a single captured retinal image that captures retinal images anterior to the vortex vein ampullae in all four quadrants.[27]  

Table

WFI and UWFI Systems Contact/ Non-contact

The Optos non-contact ultra-widefield pseudocolor fundus camera uses a scanning laser ophthalmoscope (SLO), two laser light sources of wavelengths 532 nm (green) and either 633 nm or 635 nm (red), and an ellipsoidal mirror with two conjugal focal points which enables capturing the retinal images up to 200 degrees.[32] 

Advantages of WFI and UWFI

  • Better resolution

  • Possible for image acquisition in non-compliant young pediatric patients

  • Patients with undilated pupils and hazy media due to cataracts or other diseases

  • Simultaneous imaging of central and peripheral retina; use of UWF FFA to evaluate peripheral retinal ischemia and new vessels in patients with familial exudative vitreoretinopathy, diabetic macular edema, and other vascular complications.

  • Counseling and education of the patients

Confocal scanning laser ophthalmoscope (cSLO) based fundus cameras: The confocal scanning laser ophthalmoscope (cSLO) uses laser light instead of a flashlight to illuminate the retina. This reduces the scatter of light in the images acquired, forming a sharp, high-contrast image located within the focal plane.

Currently, the imaging systems using cSLO-based fundus imaging are increasingly used. The common cSLO-based fundus cameras include Optos, the non-contact ultra-widefield fundus camera with 200 degrees field of view. This imaging system has UWF fundus imaging, choroidal imaging, fundus autofluorescence (FAF), fundus fluorescein angiography (FFA), indocyanine green (ICG) angiography, and optical coherence tomography (OCT) imaging.[33] 

If you are looking for more details, kindly visit weiqing.

Heidelberg Spectralis multi-color imaging has additional features like OCT, OCT-angiography, and fundus auto-fluorescence (FAF).

Using Mirante, the cSLO-based multimodal imaging platform, in addition to the UWF fundus photo, the additional features like FFA, ICGA, FAF, and retro mode imaging for visualizing pathologies deeper than the retinal pigment epithelium (RPE), and detecting pathologic changes in the choroid, OCT, OCT-Angiography, and an anterior segment OCT with an additional adapter can be performed.

Eidon (CenterVue) combines the cSLO with the conventional fundus imaging (white light emitting diode/LED) system to give true color-wide field fundus images. 

Red-free fundus photography (RFFP): The red-free fundus photography (RFFP) is monochromatic retinal imaging that uses gree contrast filters and enables an excellent view of the retina as the peak spectral sensitivity of the human eye falls in the green-yellow range of the spectrum. Retinal vasculature and nerve fiber layers are better seen in RFFP. The RFFP image is routinely taken as a baseline image before the FFA.[34]

Fundus autofluorescence (FAF): The FAF uses the fluorescent properties of the fluorophores. The important fluorophores in the retina are lipofuscin and melanin. Lipofuscin is a byproduct of the lysosomal breakdown of the outer photoreceptor segments within the RPE. The concentration of the lipofuscin pigments increases from the equator of the retina to the posterior pole, except for the fovea.

Lipofuscin absorbs light in the blue spectrum with a wavelength of 470 nm and emits the light in the yellow-green spectrum at a wavelength of 600 to 610 nm. Lipofuscin-based autofluorescence is known as shortwave autofluorescence (SWAF) or blue auto-fluorescence (BAF). Melanin has an excitation wavelength of 787 nm and an emission wavelength at a near-infrared wavelength. Melanin-based autofluorescence is known as near-infrared autofluorescence (NIRAF).[35] 

In BAF, the fovea is darker (hypo-autofluorescent) due to less lipofuscin at the fovea. In contrast, in NIRAF, the fovea is brighter (hyper-autofluorescent) due to the highest concentration of melanin in this region. FAF has diagnostic and prognostic utility in various diseases like central serous chorioretinopathy (CSCR), age-related macular degeneration (ARMD), retinal dystrophies, and uveitic entities like choroiditis. FAF images of the retina can be taken in a conventional fundus camera with a 50 to 55-degree field of view with the facility of FAF. UWF FAF is available in Optos, Heidelberg Spectralis, Mirante, and Clarus. 

Multi-color imaging: Multi-color imaging (MCI) uses cSLO to capture three reflectance images simultaneously 1) blue reflectance (BR; 488 nm), (2) green reflectance (GR; 515 nm), and the (3) near-infrared reflectance (IR; 820 nm). The blue reflectance enables the details of the inner retina, the green reflectance details the retinal blood vessels and exudations in the retinal layers, if any, and the infrared reflectance details the outer retina, including the RPE abnormalities. The near-infrared reflectance has been most helpful in imaging the choroidal nodules in neurofibromatosis type 1, and these nodules have been correlated with the presence of Lisch nodules of the iris.[36] 

The blue reflectance is better than the green reflectance for detecting dissociated optic nerve fiber layer after internal limiting membrane peeling.[37] Multi-color images are captured at both 30 degrees and 55 degrees in the Heidelberg Spectralis machine. In the Mirante imaging system, 163 degrees UWF multi-color images with single image capture are possible. MCI has been beneficial in diagnosing and managing diseases like ARMD, diabetic retinopathy, vitreoretinal interface disorders, retinal vein occlusions, and retinal dystrophies.[38] 

Multi-color imaging is useful in detecting vitreoretinal interface abnormalities better than posterior uveitic lesions like retinochoroiditis and retinal lesions like intraretinal hemorrhages.[39]

Smartphone-Based fundus cameras: Recently, smartphone-based fundus imaging has been proven to be a low-cost alternative to standard fundus photography. It can capture images in both the dilated and undilated pupils. It has an immense role in screening diseases like DR, ARMD, ROP, and Glaucoma. It is becoming a boon for teleophthalmology.[40] Low-cost fundus cameras have been developed to help screen for retinal diseases in remote parts of the world.[41] 

Smartphone-based fundus photography has been effective in detecting DR.[42] In smartphone-based fundus photography, the diagnostic accuracy for PDR is 92%, and that for referable DR is 91%.[43] 

Some of the FDA-approved smartphone-based fundus imaging systems include Welch Allyn iExaminer (Welch Allyn, Skaneateles Falls, NY), Remidio Fundus on device (Remidio Innovative Solutions, Bangalore, India), D-Eye, and iNview (Volk Optical, Inc.). Recently, the integration of artificial intelligence (AI) has increased the capability of fundus imaging, especially in the screening of DR.[44]

IDx-DR is an autonomous AI system that has been approved by the USFDA for the detection of DR stages more than mild DR or absence of DR. It has an imageability rate of 96.1%, a sensitivity of 87.2%, and a specificity of 90.7%.[45] USFDA cleared EyeArt (Eyenuk) for autonomous detection of more than mild DR and vision-threatening DR.[4]

Personnel

Fundus photography by a fundus camera can be performed by an ophthalmologist, optometrist, paramedical personnel, mid-level ophthalmic practitioner (MLOP), or anyone trained in ophthalmic photography.

Preparation

Before obtaining the fundus images, the patient should be informed about the procedure and the purpose of the test. The chin rest, forehead rest, and the holding support of the camera should be cleaned with an alcohol swab to maintain hygiene. If the patient wears a spectacle, they should remove the spectacle. The patient should sit and position themselves in the chinrest and forehead rest comfortably. Most fundus cameras need pupillary dilation for an optimal image free of artifacts.

Technique or Treatment

A photo of one eye of the patient is taken at a time. First, align the circle on the screen with the patient&#;s iris and pupil. Adjust the height to make the three white dots in a symmetric position. Then focus on the retina of the patient. Ask the patient to focus on the green light they see. Adjust the joystick forwards, backward, and sideways to get a sharper view of the two dots on the three o clock and nine o clock positions (to ensure the optimal distance of the camera from the eye) or a sharper image of the reticules.

There is an indicator indicating the good focus of the retina (two vertical lines which have to be aligned in some cameras). For manual capture, the eyepiece must be correctly set. The photographer must wear the refractive error corrections, if any. The accommodation of the photographer must be at rest. When the reticules are sharper, and the view of the retina is sharper, the button is pressed to capture the image (Figure-5). Fundoscopy has been taught to students using virtual platforms, which proved useful, especially during the COVID pandemic.[46]

Stereophotography uses two images taken from the right and left, which are then viewed with a stereo viewer. Optional lenses must be employed for focusing anterior objects (mid-vitreous, anterior segment). To focus posterior objects or the retina in pathological myopia, minus lenses have to be added. For extremes of refractive errors (around +15 diopter or -15 diopters), the autofocus function of the fundus camera may not work, and manual focusing should be used to focus the retina.

Complications

As a non-invasive technique, fundus cameras do not have complications. However, there is a risk of cross-infection from patients with active eye infections like conjunctivitis to the other patients who undergo fundus imaging in the same camera. Also, the strong flashlight might not be tolerable to some patients with photophobia.

Artifacts in Fundus Photography

Multiple artifacts (figure) may occur during the use of the fundus camera.

  • The orange or bright crescent at the margin of the photo is due to the illuminated iris, specifically in a poorly dilated pupil. The joystick should be moved in the opposite direction so that the cone of light passes through the pupil and does not hit the iris.

  • Eyelashes create hazy veils over some areas of the picture. The eyelids should be held open in such cases so that lashes do not obstruct the light or come in the path of the light.

  • If the camera is very near or far from the eye, there is a haze and loss of detail. The distance between the eye and camera should be optimal to get the deepest tone of color of the fundus.

  • A smudge in the system will produce a spot at the same place in the photos taken at different times. This is usually due to the touch of the objective lens by the patient's face, nose, or eyelashes, which resolves after removing the dirt or smudge from the system.

Clinical Significance

Fundus cameras are used for fundus photography. Fundus photography is useful for diagnosing, educating patients, counseling, monitoring, and forecasting many ophthalmic conditions, notably DR, ARMD, Retinal vascular disorders, ROP, and glaucoma (Figures).

The traditional tabletop fundus cameras with a 50-degree field of view can detect the pathology of the posterior pole of the eye. The wide field and ultra-widefield fundus cameras are helpful in the imaging of retinal pathology beyond the equator of the retina. The presence of predominantly peripheral lesions in DR can be detected with the help of UWFI and carries a higher risk of progression to PDR.[47] 

The contact ultra-widefield fundus camera for a neonatal eye examination (RetCam) has been used extensively for the diagnosis and follow-up of neonates at risk with and suffering from retinopathy of prematurity (ROP). This camera is portable and can be taken to remote places.   

Advances in Fundus Imaging and Future Perspectives

Bog data, machine learning, and artificial intelligence are promising in improving healthcare.[48] The integration of AI into the fundus cameras has shown good accuracy for the detection of diseases like DR. Machine learning algorithms using preoperative fundus photography along with some other preoperative data, including anterior chamber depth, central corneal depth, age, planned ablation thickness, has been shown to identify at-risk eyes for postoperative myopic regression after refractive surgery.[49] 

Deep learning algorithms using fundus photographs have been used to predict cerebral white matter hyperintensity in magnetic resonance imaging (MRI) scans.[50] A deep learning framework for the earlier detection of DR from fundus images has been developed, and it could differentiate the healthy and harmful images with 95.6% precision.[51] Studies using AI to establish the role of fundus photos, OCT, and external eye photography with systemic diseases and parameters show promising results.[52] 

AI for the screening of DR has shown a lot of promise. These findings underscore the prospective role of AI integrated fundus imaging in the screening, diagnosis, and management of different retinal diseases.[53] 

Combining OCT imaging with fundus photography has been shown to increase the efficacy of glaucoma screening.[54] This combination has also been shown to effectively diagnose cases of high myopia with retinopathy.[55] This approach demonstrates the beneficial role of multi-modal imaging. Studies on handheld fundus cameras are on the rise. Comparative studies have shown that the handheld fundus camera effectively diagnoses referrable cases of DR.[56] 

Similarly, smartphone-based fundus imaging is on the rise and is most useful for teleophthalmology. However, in detecting ROP, though the smartphone-based cameras provide a moderate agreement for the detection of the presence or absence of plus disease, they failed to identify the stages and zones of the disease.[57]

Enhancing Healthcare Team Outcomes

The fundus camera plays an important role in diagnosing and managing ophthalmic diseases. Apart from the ophthalmologists, optometrists, ophthalmic photographers, and paramedical workers are involved in taking images in the fundus cameras. While doing fundus fluorescein angiography or indocyanine green angiography, the nurses should be aware of the possible side effects of the dye-related invasive procedure.[29][30] 

Coordination between all the team members and caregivers and updating their knowledge about the fundus photography and procedures related to the fundus cameras is crucial.

Nursing, Allied Health, and Interprofessional Team Interventions

Nurses are involved in the procedure of fundus photography. Their support during any side effects of the procedures like fundus fluorescein angiography is vital. They should possess strong knowledge regarding the emergency medicines needed during any complications related to the investigations.

Retinal diseases are associated with various systemic illnesses like diabetes, systemic hypertension, and systemic drug toxicity. Clinical history provided by colleagues from specialties other than ophthalmology will help interpret the fundus images.

Nursing, Allied Health, and Interprofessional Team Monitoring

The fundus camera is used for non-invasive procedures like fundus photography and invasive procedures like FFA. Monitoring the quality of images taken, the indications for which the images are taken, a note of any adverse events, and their management is crucial for operating a fundus photography unit. Nurses, allied health personnel, ophthalmologists, and doctors from other specialties can use the fundus camera. An audit and monitoring of the events happening in the fundus photography unit are crucial for the smooth functioning of the unit.

Figure

Illumination and imaging of the retina through the pupil Contributed by Dr. Chitaranjan Mishra, DNB

Figure

A Fundus camera in the clinic Contributed by Chitaranjan Mishra, DNB, FICO, MRCS Ed

Figure

Parts of a fundus camera are shown in a schematic diagram of a typical fundus camera Contributed by Contributed by Chitaranjan Mishra, DNB, FICO, MRCS Ed

Figure

Fundus photo being taken in a fundus camera by the photographer Contributed by Chitaranjan Mishra, DNB, FICO, MRCS Ed

Figure

Optics of fundus camera Contributed by Chitaranjan Mishra, MS

Disclosure: Chitaranjan Mishra declares no relevant financial relationships with ineligible companies.

Disclosure: Koushik Tripathy declares no relevant financial relationships with ineligible companies.

If you are looking for more details, kindly visit Retinal Camera.